Forum Post: Compiler/TMS320F28377S: static code analysis tool

$
0
0
Part Number: TMS320F28377S Tool/software: TI C/C++ Compiler Is there a static code analysis tool that works well with CCS/embedded C. I searched the internet. But did not find any that looks useful for embedded systems. Thanks!

Forum Post: CCS/MOTORWARE: Add Header file, source file

$
0
0
Part Number: MOTORWARE Tool/software: Code Composer Studio I have used motorware instaspin. I want to add header file(.h) and source file(.c) in the controlsuite .. There are too many errors when I try. that is, I would like to add the header file (.h) and source file (.c) in the controlsuite (F2806x_common and F2806x_headers) to the motorware . Should I put it in C:\ti\ motorware \motorware_1_01_00_18\sw\modules? Should I put it in C:\ti\ motorware \motorware_1_01_00_18\sw\drivers? Should I put it in C:\ti\ motorware \motorware_1_01_00_18\sw\solutions?

Forum Post: TMS570LS1224: TMS570LS1224

$
0
0
Part Number: TMS570LS1224 How can we set a single pin of PORTA to high or low??

Forum Post: CCS/LAUNCHXL-F280049C: LAUNCHXL-F280049C

$
0
0
Part Number: LAUNCHXL-F280049C Tool/software: Code Composer Studio Hi, I am using CCS8.2 and I am unable to make connection to F280049C. Kindly advise. Thanks [Start: Texas Instruments XDS110 USB Debug Probe_0] Execute the command: %ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -rv -o -S integrity [Result] -----[Print the board config pathname(s)]------------------------------------ C:\Users\AppData\Local\TEXASI~1\CCS\ TI\0\0\BrdDat\testBoard.dat -----[Print the reset-command software log-file]----------------------------- This utility has selected a 100- or 510-class product. This utility will load the adapter 'jioxds110.dll'. The library build date was 'May 30 2018'. The library build time was '23:03:35'. The library package version is '8.0.27.9'. The library component version is '35.35.0.0'. The controller does not use a programmable FPGA. The controller has a version number of '5' (0x00000005). The controller has an insertion length of '0' (0x00000000). This utility will attempt to reset the controller. This utility has successfully reset the controller. -----[Print the reset-command hardware log-file]----------------------------- The scan-path will be reset by toggling the JTAG TRST signal. The controller is the XDS110 with USB interface. The link from controller to target is direct (without cable). The software is configured for XDS110 features. The controller cannot monitor the value on the EMU[0] pin. The controller cannot monitor the value on the EMU[1] pin. The controller cannot control the timing on output pins. The controller cannot control the timing on input pins. The scan-path link-delay has been set to exactly '0' (0x0000). -----[An error has occurred and this utility has aborted]-------------------- This error is generated by TI's USCIF driver or utilities. The value is '-233' (0xffffff17). The title is 'SC_ERR_PATH_BROKEN'. The explanation is: The JTAG IR and DR scan-paths cannot circulate bits, they may be broken. An attempt to scan the JTAG scan-path has failed. The target's JTAG scan-path appears to be broken with a stuck-at-ones or stuck-at-zero fault. [End: Texas Instruments XDS110 USB Debug Probe_0]

Forum Post: TMS320F28377D: Digital filters

$
0
0
Part Number: TMS320F28377D How to implement the digital filter coefficients to the program files?

Forum Post: EVM430-F6736: Cannot connect RS232 on EVM430 board to PC

$
0
0
Part Number: EVM430-F6736 Hi all, I have using EVM430F6736 development board. In this board at serial communication, the connection between the board to PC using Rs232 to RS232. I doesn't set the AC setup... I just powered the board by DC supply because of for serial communication, MCU need only DC supply...when I Powered the board, Comm part of GUI doesn't turn green.. still it become red on comm part. 1.How to get the green on Comm Part at GUI?? is any problem i made for the connection?? Thanks & Regards, Poovai Anitha.L

Forum Post: EVM430-F6736: GUI calibration.exe file isn't open on my PC

$
0
0
Part Number: EVM430-F6736 Hi all, I'm using EVM430F6736 energy meter. I want to display the EVM calibrated data to GUI.. I'm using the firmware SLAA517.. but in this calibration.exe file isn't open on my PC ( windows 10).. but it opened on windows 7 PC.. Is this executable file became compatile only for earlier windows ? IS any possible solution to open these file on my windows PC. Thanks & Regards, Anitha.L

Forum Post: RE: CCS/TMS320F28027: Programming flash memory

$
0
0
Hello Ozino, Thanks for your reply. I'm running the code provided by C2000Ware , and I have not made any alterations to it. What is your thoughts one the disabled watchdog, should it effect the program? Could there be a setting which is wrong or a file which isn't linked in the correct way?

Forum Post: CCS/TMS320F28334: Need clarification on the different HEX conversion formats (hex2000.exe)

$
0
0
Part Number: TMS320F28334 Tool/software: Code Composer Studio Hi, Support Team, 1. Does the content of .txt file and .hex file generated by below method have same ? hex2000.exe -boot -sci8 -a -o application.txt application.out hex2000.exe -romwidth 16 -i -o application.hex application.out 2. Does TI has any other tool to download .hex file directly into controller (instead of using serial_flash_programmer.exe)? 3. Does TI has any other tool for converting ".out" to ".txt" format(instead of using hex2000.exe) ? Awaiting for your quick reply. Thank you, Regards, Bhanu

Forum Post: RE: CCS/UNIFLASH: How prevent "Run Target After Program Load/Flash Operation" from command line interface?

$
0
0
Hello Max, unfortunately this is something we cannot prevent from UniFLASH . After executing the FLASH operation the system will "exit". Thus the target will always start with code execution after the FLASH activities are completed. Best regards Peter

Forum Post: RE: MSP430FR2633: Sample Capacitor = Reference Capacitor?

$
0
0
Hello Canbey, there is a technical reason for the difference in the values. This relates to the measurement method and conditions with mutual capacitance, where the values of the typical sensors/electrodes are in a different capacitance range, and also related to the fact that with mutual capacitance you need some self capacitance at the RX electrode, to be able to use the charge transfer with the TX-RX approach. The respective definitions for the reference capacitors can be found also in our libraries. Best regards Peter

Forum Post: RE: Compiler/MSP430G2231: Push Button doesn't change LED state

$
0
0
Hi Jucimar, have you been able to solve the problem based on my recommendation? Please let me know, whether you need further support on this. Many thanks in advance. Best regards Peter

Forum Post: RE: TMDSHVMTRPFCKIT: Conversion to TI per-unit.

Forum Post: RE: MSP430F5359: clarification about BSL14 errata

$
0
0
Hi Lorenzo, there is a bug with the respective device and the BSL implementation. Due to a change in the BSL, the feature supporting reopening of the JTAG, which has been locked before is not working. Means once you have locked the JTAG, you cannot re-open it using the BSL communication. So addressing your questions: The JTAG is open with a non-programmed device from factory, and remains open, until you close it by intention. After that, with the affected devices, like with the MSP430F5359 , it cannot be re-opened by TI's integrated BSL. Best regards Peter

Forum Post: RE: TMS320F28377D: DC Event Delaying Using Valley Switching Submodule

$
0
0
Hi, Is there any improvement with the issue?

Forum Post: RE: CCS/TMS320F280049: CLA code will single step only

$
0
0
Hi, I haven’t heard from you for a few days, so I’m assuming you were able to resolve your issue. If this isn’t the case, please click the "This did NOT resolve my issue" button and reply to this thread with more information. If this thread locks, please click the "Ask a related question" button and in the new thread describe the current status of your issue and any additional details you may have to assist us in helping to solve your issues. Regards, Praveen

Forum Post: RE: TM4C1294NCPDT: 100Base-TX Full Duplex Auto MDI-X problem

$
0
0
I have an update. I have tried to change the init sequence according to some random code that I have found on these forums. The link up time is now roughly 10 seconds. This doesn't make much sense to me as I am deviating from what datasheet specifies as correct PHY configuration sequence. Nevertheless 10 seconds is still 2,5 times the time that IEEE 802.3 allows. The new initialization is as follows (up to the physical address setting. After that everything is kept the same): // Enable and reset the Ethernet modules MAP_SysCtlPeripheralEnable(SYSCTL_PERIPH_EMAC0); MAP_SysCtlPeripheralReset(SYSCTL_PERIPH_EMAC0); MAP_SysCtlPeripheralEnable(SYSCTL_PERIPH_EPHY0); MAP_SysCtlPeripheralReset(SYSCTL_PERIPH_EPHY0); while(!MAP_SysCtlPeripheralReady(SYSCTL_PERIPH_EMAC0)) {} MAP_EMACPHYConfigSet(EMAC0_BASE, (EMAC_PHY_TYPE_INTERNAL | EMAC_PHY_INT_MDIX_EN | EMAC_PHY_INT_ROBUST_MDIX | EMAC_PHY_FORCE_100B_T_FULL_DUPLEX)); // init EMAC MAP_EMACInit(EMAC0_BASE, ADN_SYS_CORE_FREQ, (EMAC_BCONFIG_FIXED_BURST | EMAC_BCONFIG_PRIORITY_FIXED), 1, 1, 0); // configure EMAC MAP_EMACConfigSet(EMAC0_BASE, (EMAC_CONFIG_100MBPS | EMAC_CONFIG_FULL_DUPLEX | EMAC_CONFIG_CHECKSUM_OFFLOAD | EMAC_CONFIG_USE_MACADDR0 | EMAC_CONFIG_STRIP_CRC), (EMAC_MODE_RX_STORE_FORWARD | EMAC_MODE_TX_STORE_FORWARD | EMAC_MODE_RX_FLUSH_DISABLE), 0);

Forum Post: RE: CCS/CC430F5137: Is there any method to flash CC430F5137 with increased number at certain flash address with TI's Uniflash_4.6.0?

$
0
0
Hello, you're right. The serialization is an important feature. We're supporting this feature for the MSP430 with the production programmer from TI called Gang Programmer MSP-GANG www.ti.com/.../msp-gang Potentially we will integrate this feature in UniFLASH too at some point of time, but currently there is no schedule for this. Best regards Peter

Forum Post: RE: RM46L852: Selectively suppressing mibSPI RX overrun

$
0
0
Hello, Could you attache your project, so I can debug this scenario? Best regards, Miro

Forum Post: RE: Compiler/TMS320F28377S: static code analysis tool

$
0
0
Hi, The CCS itself has some static analysis checks like MISRA C. You can navigate to project properties -> Build -> C2000 compiler -> Advanced options -> MISRA C 2004. You can enable the necessary rules and the they will be checked during compilation. There are other 3rd party tools like LDRA, Klockworks etc being used for static analysis. Regards, Veena