Quantcast
Channel: Microcontrollers
Viewing all 217813 articles
Browse latest View live

Forum Post: RE: SYSCONFIG: SysConfig crash when enabling clock tree for MSPM03519

$
0
0
Hi Eugene, Could you please descript the steps you get this error. From my side, after I open sysconfig 1.22.0+3893, the highest SDK version it support is v2.02.00.05. I am not sure how you get use of mspm0_sdk_2_03_00_07 SDK. By the way, the most common way we use sysconfig is to use its built-in version in CCS when opening SDK examples: Best Regards, Pengfei

Forum Post: MSP430F5310: IAR download error

$
0
0
Part Number: MSP430F5310 Other Parts Discussed in Thread: MSP-FET Tool/software: 1. Design setting - MCU : MSP430F5310 - IAR : 6.50.1 - Download tool : MSP-FET 2. MSP-FET connection 2. Error - The error occured when downloading with IAR 3. Checked point before asking - No error in Debugger setup in IAR options. - IAR Licence version is 7.10, but IAR installation version is 6.50.1 - when I first run the download, IAR asked me that FW(?) was updated, so I run it Please, let me know the solution. Thanks

Forum Post: TM4C1294NCPDT: max ethernet speed 1gbps

$
0
0
Other Parts Discussed in Thread: TM4C1294NCPDT Tool/software: Hi, I am using TM4C1294NCPDT for Ethernet Application, but it is supporting 100 mbps speed. My requirement 1GBPS. Can you suggest any tiva series micro controller which will support 1GBPS speed. Please give detail explaination .

Forum Post: RE: TMS320F28388D: What happens if the AUXPLLRAWCLK or SYSPLLRAWCLK is not 100 MHz for Ethernet Clocking input ?

$
0
0
I have not yet received a response . Could you please provide an update on the status of my queries? If any further information is needed from my side, I would be happy to provide it. Thank you for your attention to this matter. I look forward to your prompt response. Best regards, Aditya

Forum Post: TMS320F28027F: TMS320F28027with DRV8301 to run bldc motor

$
0
0
Part Number: TMS320F28027F Other Parts Discussed in Thread: MOTORWARE Tool/software: I am working with examples from Motorware and want to run the motor without using the GUI method. If possible, I would like clarification on how to operate the examples without relying on the GUI process. Can anyone guide me on how to do this?

Forum Post: RE: TMS320F280039C: Is it possible to integrate the PFC and LLC controllers into one in PMP41006?

$
0
0
Hi Yukio Oyama san, From system level we should also analyze the cost of the isolators. Isolation would either move to the communication or to the gate driver/feedback sensors. Since we have both the C28x and CLA, one of them can run the PFC and another the LLC. In this case both controllers can run independently. It might also be possible to combine both PFC and LLC in one C28x, in this case we need to ensure that the ISRs for both are synchronous and get completed within the time available for calculation. Does your system also need to do other housekeeping, communication tasks - some bandwidth would need to be reserved for this as well. May I ask the power levels, is it 3 phase input? Which topology do you plan for the PFC and isolated DC/DC? Also, I would recommend the latest device TMS320F28P550SJ data sheet, product information and support | TI.com which will provide a clock frequency of 150MHz. Best regards, Pawan

Forum Post: RE: AM2432: change flash to IS25LP128

$
0
0
Hi Tomoya, I could reproduce this issue at my end, please give me some time to further investigate, what could be the issue. I used MCU + SDK version 10.0.0, could you please let me know which version you are testing on? Best Regards, Meet.

Forum Post: RE: F29H85X-SOM-EVM: INT type interrupt triggers exception.

$
0
0
Aishwarya, I have resolved the issue,no more questions.Thank you for your help. Best Regards, Zihao

Forum Post: RE: SYSCONFIG: SYSCONFIG says its missing EMIF pin signals D16-D31 when I specified I use a 16-bit SDRAM

$
0
0
Hello Anand I appreciate you replying to my concern. I made the necessary updates to my .syscfg file. It seems to be working with the custom use case now. Thanks again. Have a great week ahead. Best, Nalin Prabhath

Forum Post: RE: LP-AM243: AM243x

$
0
0
Hi Rajul, Thanks for your reply. Is it possible to make multicore nortos system project combining "C:\ti\motor_control_sdk_am243x_09_02_00_09\examples\tidep_01032_dual_motor_drive\single_chip_servo\am243x-lp\r5fss0-1_nortos" + "C:\ti\motor_control_sdk_am243x_09_02_00_09\examples\position_sense\bissc_diagnostic\single_channel\am243x-lp\r5fss0-0_freertos" without the DPL procedure (for Biss-C code) you described? Regards, Vedat

Forum Post: TMS320F28377D: explore the use of dual core for memory usage

$
0
0
Part Number: TMS320F28377D Tool/software: Hi, I am working on a project where in CPU1 (512KB) is used. Application size needs more size ; I am in need to know how to use CPU 2 memory (another 512 KB) for same application. Can someone please guide on this. Thanks to Support Team

Forum Post: RE: TMS320F28P550SJ: Configurable Logic Block (CLB) - How do I get started?

$
0
0
Hi Lori, Over the past two days, I have carried out a comprehensive examination and reflection on the CLB design. Eventually, I discovered that in the tformat_f28p65x_comms_demo project, the SPI data width is configured as 16 bits. However, according to the communication design, it should be 10 bits. After my modification, the tformat communication returned to normal. I have a question regarding this. In the PM_TFORMAT_CLB_init function within board.c, why is it necessary to configure the GolbalInputMux as CLB_GLOBAL_IN_MUX_EPWM1A? Moreover, I would like to ask where the Endat - related routines and relevant documents are in the CLB examples. I couldn't find them in the MotorControl_SDK_5.03. I'm truly grateful for your timely replies and assistance these days. Sincerely appreciate it. Best regards, Lin Haonan

Forum Post: RE: LP-AM243: How to use ADC0_AIN as Digital Input

$
0
0
Hi Oyama-San, Ideally this should work, could you please provide me more details on your test and how you are verifying that AIN0 is not working, I can try to test the same at my end to verify the same. Best regards, Meet.

Forum Post: RE: AM2432: change flash to IS25LP128

$
0
0
Hi Meet, I use mcu_plus_sdk in the ind_comms_sdk_am243x_09_02_00_15. By changing condition of if() in the ospi_flash_diag.c like bellow, I could read .json data. But, data mismatch still has been happened, so this .json data might be wrong. if(1) { /* Read the SFDP table and print flash details */ status = ospi_flash_diag_print_sfdp(ospiHandle); } Best regards, Oyama

Forum Post: RE: CC33XX-SOFTWARE: Requesting for migration guide for AM243X Version 10 SDK to interface AM243X-LP With CC33XX-BP

$
0
0
Hi AB, Thank you for your response. Yes, I build all the required files such as, wifi_host_driver, wifi_platform_cc33xx, wifi_stack_interface, ble_host_nimble and ble_interface and cc3xxx_network_terminal in the configuration of AM243x 10.01 SDK, Compiler version - TI Clang V4.0.1.LTS and SysConfig version - 1.22.0, which supports version 10 SDK of AM243x. But, while compiling cc3xxx _network_terminal file getting warning to change sysconfig version. But AM243x version 10 SDK supports sysconfig- 1.22.0 version. I have attached the compilation error below.

Forum Post: RE: TMS320F28379S: Issue with Serial Flash Programming using SCI Bootloader example from C2000ware

$
0
0
Hi Charles, SCI Boot Mode & Serial Flash Programmer I’ve tried using the " serial_flash_programmer.exe" as you suggested, but the issue remains the same. Additionally, I also experimented with a reduced baud rate, but that didn’t resolve the problem either. GPIOs for SCI Communication The boot mode is set to SCI, with GPIO 72 set to 0 and GPIO 84 set to 1 for SCI communication. Kernel Communication GPIOs I’ve verified both the code and hardware for the SCI pins (GPIO 28 and 29), and everything seems to be in order. I also confirmed that SCI communication works when tested with terminal software. Thanks.

Forum Post: RE: LP-AM243: How to use ADC0_AIN as Digital Input

$
0
0
Hi Meet, I use "gpio_input_interrupt", and change GPIO peripherals in the sysconfig, and connect +3.3V and target pin by cable. For example, changing to J3 pin, and plugging and unplugging a cable, it worked. But, changing to ADC0_AIN0/H21 pin, it doesn't work. Best regard, oyama

Forum Post: RE: MSPM0L1306: mspm0l1306

$
0
0
Hi, Have you imported your original project into the new CCS workspace? And could you please show the error information shown in CCS? Regards, Zoey

Forum Post: RE: MSPM0C1104: Add TIMER-PWM in my project but not working

$
0
0
You can use the digital multimeter to test the average voltage for this pins

Forum Post: RE: MSPM0G3507-Q1: 120° Phase shifting of three PWMs

$
0
0
Hi Fabio, We do not have this demo code. You can use the timer different channel: 1. One is to output PWM 2. The other will have interrupt once the 120°phase is coming, and try to start another timer. Regards, Zoey
Viewing all 217813 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>