Hello Canbey, There is one reference capacitor circuit per device and you can configure which block it connects to. Let's say if you have an btn00_E0 element and it is assigned to Block 0. When you set ref cap to btn00_E0, it will connect to Block 0. As far as the ref cap size, I think there is typo in the function comment section which we will fix it in next release. I will recommend to use the Reference Capacitor Sizes flags to pass the size to the function. The flags are in CAPT_HAL.h line 116 - 125. Thanks, Yiding
↧